Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Commun Med (Lond) ; 3(1): 147, 2023 Oct 17.
Artigo em Inglês | MEDLINE | ID: mdl-37848608

RESUMO

BACKGROUND: Absolute temperature measurements of tissues inside the human body are difficult to perform non-invasively. Yet, for brown adipose tissue (BAT), these measurements would enable direct monitoring of its thermogenic activity and its association with metabolic health. METHODS: Here, we report direct measurement of absolute BAT temperature in humans during cold exposure by magnetic resonance (MR) with laser polarized xenon gas. This methodology, which leverages on the sensitivity of the chemical shift of the 129Xe isotope to temperature-induced changes in fat density, is first calibrated in vitro and then tested in vivo in rodents. Finally, it is used in humans along with positron emission tomography (PET) scans with fluorine-18-fluorodeoxyglucose to detect BAT thermogenic activity during cold exposure. RESULTS: Absolute temperature measurements, obtained in rodents with an experimental error of 0.5 °C, show only a median deviation of 0.12 °C against temperature measurements made using a pre-calibrated optical temperature probe. In humans, enhanced uptake of 129Xe in BAT during cold exposure leads to background-free detection of this tissue by MR. Global measurements of supraclavicular BAT temperature, made over the course of four seconds and with an experimental error ranging from a minimum of 0.4 °C to more than 2 °C, in case of poor shimming, reveal an average BAT temperature of 38.8° ± 0.8 °C, significantly higher (p < 0.02 two-sided t test) than 37.7 °C. Hot BAT is also detected in participants with a PET scan negative for BAT. CONCLUSIONS: Non-invasive, radiation-free measurements of BAT temperature by MRI with hyperpolarized 129Xe may enable longitudinal monitoring of human BAT activity under various stimulatory conditions.


Brown adipose tissue (BAT) is a fat tissue specialized in heat production and considered a potential target for the treatment of obesity and diabetes. Detection of this tissue and its metabolic activity in adult humans is challenging as this tissue is often mixed with white fat, which makes up most of the fat in adult humans. Here we demonstrate that magnetic resonance imaging with laser-polarized xenon gas, a medical imaging technique used to assess lung ventilation function, can detect the presence of this tissue in humans and measure its temperature. These temperature measurements, which show that brown fat becomes significantly hotter than 37 °C when humans are exposed to cold, may be useful in future studies to assess the effects of drugs that aim to target BAT's heat-generating activity to regulate blood sugar level.

2.
J Magn Reson ; 332: 107076, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34624719

RESUMO

In recent years, low field and ultra-low field NMR spectrometers have gained interest due to their portability, lower cost, and reduced subject-induced magnetic field inhomogeneities. Here, we describe the design of a low-cost multinuclear NMR spectrometer operating in the ultra-low field regime (ULF), which possesses high spectral resolution and enables arbitrary pulse programming. An inexpensive multifunction input/output (I/O) device is used to handle waveform generation and digitization in the kHz operating range. A home-built radio frequency (RF) mixing circuit is used to down-mix the NMR signals, allowing for the slower sampling rates and lower memory requirements needed to enable minute-long acquisitions using a standard Windows PC. The LabVIEW code, along with a bill of materials for all components used in the spectrometer, is included. As proof of concept, 1H relaxation measurements and the simultaneous detection of 1H with gas phase and dissolved 129Xe frequencies using the described low field NMR spectrometer are demonstrated.

3.
Magn Reson Med ; 85(2): 1028-1038, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-32770779

RESUMO

PURPOSE: To quantitatively compare dynamic 19 F and single breath hyperpolarized 129 Xe MRI for the detection of ventilation abnormalities in subjects with mild cystic fibrosis (CF) lung disease. METHODS: Ten participants with stable CF and a baseline FEV1 > 70% completed a single imaging session where dynamic 19 F and single breath 129 Xe lung ventilation images were acquired on a 3T MRI scanner. Ventilation defect percentages (VDP) values between 19 F early-breath, 19 F maximum-ventilation, 129 Xe low-resolution, and 129 Xe high-resolution images were compared. Dynamic 19 F images were used to determine gas wash-in/out rates in regions of ventilation congruency and mismatch between 129 Xe and 19 F. RESULTS: VDP values from high-resolution 129 Xe images were greater than from low-resolution images (P = .001), although these values were significantly correlated (r = 0.68, P = .03). Early-breath 19 F VDP and max-vent 19 F VDP also showed significant correlation (r = 0.75, P = .012), with early-breath 19 F VDP values being significantly greater (P < .001). No correlation in VDP values were detected between either 19 F method or high-res 129 Xe images. In addition, the location and volume of ventilation defects were often different when comparing 129 Xe and 19 F images from the same subject. Areas of ventilation congruence displayed the expected ventilation kinetics, while areas of ventilation mismatch displayed abnormally slow gas wash-in and wash-out. CONCLUSION: In CF subjects, ventilation abnormalities are identified by both 19 F and HP 129 Xe imaging. However, these ventilation abnormalities are not entirely congruent. 19 F and HP 129 Xe imaging provide complementary information that enable differentiation of normally ventilated, slowly ventilated, and non-ventilated regions in the lungs.


Assuntos
Fibrose Cística , Fibrose Cística/diagnóstico por imagem , Humanos , Pulmão/diagnóstico por imagem , Imageamento por Ressonância Magnética , Respiração , Isótopos de Xenônio
4.
Sci Rep ; 9(1): 14865, 2019 10 16.
Artigo em Inglês | MEDLINE | ID: mdl-31619741

RESUMO

Brown adipose tissue (BAT) is a type of fat specialized in non-shivering thermogenesis. While non-shivering thermogenesis is mediated primarily by uncoupling protein 1 (UCP1), the development of the UCP1 knockout mouse has enabled the study of possible UCP1-independent non-shivering thermogenic mechanisms, whose existence has been shown so far only indirectly in white adipose tissue and still continues to be a matter of debate in BAT. In this study, by using magnetic resonance thermometry with hyperpolarized xenon, we produce the first direct evidence of UCP1-independent BAT thermogenesis in knockout mice. We found that, following adrenergic stimulation, the BAT temperature of knockout mice increases more and faster than rectal temperature. While with this study we cannot exclude or separate the physiological effect of norepinephrine on core body temperature, the fast increase of iBAT temperature seems to suggest the existence of a possible UCP1-independent thermogenic mechanism responsible for this temperature increase.


Assuntos
Tecido Adiposo Marrom/metabolismo , Espectroscopia de Ressonância Magnética/métodos , Termogênese/genética , Termometria/métodos , Proteína Desacopladora 1/genética , Tecido Adiposo Marrom/efeitos dos fármacos , Agonistas alfa-Adrenérgicos/farmacologia , Animais , Feminino , Expressão Gênica , Masculino , Camundongos , Camundongos Knockout , Norepinefrina/farmacologia , Termogênese/efeitos dos fármacos , Termometria/instrumentação , Proteína Desacopladora 1/deficiência , Xenônio
5.
Magn Reson Med ; 81(2): 765-772, 2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-30216528

RESUMO

PURPOSE: Absolute MR temperature measurements are currently difficult because they require precalibration procedures specific for tissue types and conditions. Reference of the lipid-dissolved 129 Xe resonance frequency to temperature-insensitive methylene protons (rLDX) has been proposed to remove the effect of macro- and microscopic susceptibility gradients to obtain absolute temperature information. The scope of this work is to evaluate the rLDX chemical shift (CS) dependence on lipid composition to estimate the precision of absolute temperature measurements in lipids. METHODS: Neat triglycerides, vegetable oils, and samples of freshly excised human and rodent adipose tissue (AT) are prepared under 129 Xe atmosphere and studied using high-resolution NMR. The rLDX CS is measured as a function of temperature. 1 H spectra are also acquired and the consistency of methylene-referenced water proton and rLDX CS values are compared in human AT. RESULTS: Although rLDX CS shows a dependence on lipid composition, in human and rodent AT samples the rLDX shows consistent CS values with a similar temperature dependence (-0.2058 ± 0.0010) ppm/°C × T (°C) + (200.15 ± 0.03) ppm, enabling absolute temperature measurements with an accuracy of 0.3°C. Methylene-referenced water CS values present variations of up to 4°C, even under well-controlled conditions. CONCLUSIONS: The rLDX can be used to obtain accurate absolute temperature measurements in AT, opening new opportunities for hyperpolarized 129 Xe MR to measure tissue absolute temperature.


Assuntos
Lipídeos/química , Imageamento por Ressonância Magnética , Xenônio , Tecido Adiposo/metabolismo , Animais , Calibragem , Humanos , Óleos de Plantas/química , Prótons , Ratos , Valores de Referência , Reprodutibilidade dos Testes , Temperatura , Triglicerídeos/química , Água/química
6.
J Magn Reson ; 291: 53-62, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-29702362

RESUMO

SuperParamagnetic Iron Oxide Nanoparticles (SPIONs) are often used in magnetic resonance imaging experiments to enhance Magnetic Resonance (MR) sensitivity and specificity. While the effect of SPIONs on the longitudinal and transverse relaxation time of 1H spins has been well characterized, their effect on highly diffusive spins, like those of hyperpolarized gases, has not. For spins diffusing in linear magnetic field gradients, the behavior of the magnetization is characterized by the relative size of three length scales: the diffusion length, the structural length, and the dephasing length. However, for spins diffusing in non-linear gradients, such as those generated by iron oxide nanoparticles, that is no longer the case, particularly if the diffusing spins experience the non-linearity of the gradient. To this end, 3D Monte Carlo simulations are used to simulate the signal decay and the resulting image contrast of hyperpolarized xenon gas near SPIONs. These simulations reveal that signal loss near SPIONs is dominated by transverse relaxation, with little contribution from T1 relaxation, while simulated image contrast and experiments show that diffusion provides no appreciable sensitivity enhancement to SPIONs.


Assuntos
Meios de Contraste/química , Imagem de Difusão por Ressonância Magnética/métodos , Nanopartículas de Magnetita/química , Xenônio/química , Algoritmos , Simulação por Computador , Difusão , Campos Eletromagnéticos , Gases/química , Imagens de Fantasmas
7.
Proc Natl Acad Sci U S A ; 115(1): 174-179, 2018 01 02.
Artigo em Inglês | MEDLINE | ID: mdl-29255046

RESUMO

Detection and quantification of brown adipose tissue (BAT) mass remains a major challenge, as current tomographic imaging techniques are either nonspecific or lack the necessary resolution to quantify BAT mass, especially in obese phenotypes, in which this tissue may be present but inactive. Here, we report quantification of BAT mass by xenon-enhanced computed tomography. We show that, during stimulation of BAT thermogenesis, the lipophilic gas xenon preferentially accumulates in BAT, leading to a radiodensity enhancement comparable to that seen in the lungs. This enhancement is mediated by a selective reduction in BAT vascular resistance, which greatly increases vascular perfusion of BAT. This enhancement enables precise identification and quantification of BAT mass not only in lean, but also in obese, mouse phenotypes, in which this tissue is invisible to conventional tomographic imaging techniques. The method is developed and validated in rodents and then applied in macaques to assess its feasibility in larger species.


Assuntos
Tecido Adiposo Marrom/diagnóstico por imagem , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Xenônio , Animais , Macaca , Camundongos Obesos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/instrumentação
8.
Magn Reson Med ; 80(2): 431-441, 2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-29266425

RESUMO

PURPOSE: To assess the effect of macroscopic susceptibility gradients on the gas-phase referenced dissolved-phase 129 Xe (DPXe) chemical shift (CS) and to establish the robustness of a water-based referencing system for in vivo DPXe spectra. METHODS: Frequency shifts induced by spatially varying magnetic susceptibility are calculated by finite-element analysis for the human head and chest. Their effect on traditional gas-phase referenced DPXe CS is then assessed theoretically and experimentally. A water-based referencing system for the DPXe resonances that uses the local water protons as reference is proposed and demonstrated in vivo in rats. RESULTS: Across the human brain, macroscopic susceptibility gradients can induce an apparent variation in the DPXe CS of up to 2.5 ppm. An additional frequency shift as large as 6.5 ppm can exist between DPXe and gas-phase resonances. By using nearby water protons as reference for the DPXe CS, the effect of macroscopic susceptibility gradients is eliminated and consistent CS values are obtained in vivo, regardless of shimming conditions, region of interest analyzed, animal orientation, or lung inflation. Combining in vitro and in vivo spectroscopic measurements finally enables confident assignment of some of the DPXe peaks observed in vivo. CONCLUSION: To use hyperpolarized xenon as a biological probe in tissues, the DPXe CS in specific organs/tissues must be reliably measured. When the gas-phase is used as reference, variable CS values are obtained for DPXe resonances. Reliable peak assignments in DPXe spectra can be obtained by using local water protons as reference. Magn Reson Med 80:431-441, 2018. © 2017 International Society for Magnetic Resonance in Medicine.


Assuntos
Imageamento por Ressonância Magnética/métodos , Isótopos de Xenônio/química , Animais , Encéfalo/diagnóstico por imagem , Cabeça/diagnóstico por imagem , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Ratos , Ratos Endogâmicos F344 , Processamento de Sinais Assistido por Computador , Tórax/diagnóstico por imagem
9.
Magn Reson Med ; 78(3): 1070-1079, 2017 09.
Artigo em Inglês | MEDLINE | ID: mdl-27759913

RESUMO

PURPOSE: To investigate the temperature dependence of the resonance frequency of lipid-dissolved xenon (LDX) and to assess the accuracy of LDX-based MR thermometry. METHODS: The chemical shift temperature dependence of water protons, methylene protons, and LDX was measured from samples containing tissues with varying fat contents using a high-resolution NMR spectrometer. LDX results were then used to acquire relative and absolute temperature maps in vivo and the results were compared with PRF-based MR thermometry. RESULTS: The temperature dependence of proton resonance frequency (PRF) is strongly affected by the specific distribution of water and fat. A redistribution of water and fat compartments can reduce the apparent temperature dependence of the water chemical shift from -0.01 ppm/°C to -0.006 ppm, whereas the LDX chemical shift shows a consistent temperature dependence of -0.21 ppm/°C. The use of the methylene protons resonance frequency as internal reference improves the accuracy of LDX-based MR thermometry, but degrades that of PRF-based MR thermometry, as microscopic susceptibility gradients affected lipid and water spins differently. CONCLUSION: The LDX resonance frequency, with its higher temperature dependence, provides more accurate and precise temperature measurements, both in vitro and in vivo. More importantly, the resonance frequency of nearby methylene protons can be used to extract absolute temperature information. Magn Reson Med 78:1070-1079, 2017. © 2016 International Society for Magnetic Resonance in Medicine.


Assuntos
Imageamento por Ressonância Magnética/métodos , Termometria/métodos , Isótopos de Xenônio/química , Tecido Adiposo/diagnóstico por imagem , Animais , Temperatura Corporal/fisiologia , Simulação por Computador , Feminino , Camundongos , Camundongos Obesos , Prótons , Isótopos de Xenônio/metabolismo
10.
J Chem Phys ; 145(19): 194201, 2016 Nov 21.
Artigo em Inglês | MEDLINE | ID: mdl-27875871

RESUMO

A remote detection scheme utilizing the distant dipolar field interaction between two different spin species was proposed by Granwehr et al. [J. Magn. Reson. 176(2), 125 (2005)]. In that sequence 1H spins were detected indirectly via their dipolar field interaction with 129Xe spins, which served as the sensing spins. Here we propose a modification of the proposed detection scheme that takes advantage of the longer T1 relaxation time of xenon to create a long lasting dipolar field with which the fast relaxing 1H spins are allowed to interact many times during a single acquisition. This new acquisition scheme improves detection sensitivity, but it also presents some challenges.

SELEÇÃO DE REFERÊNCIAS